Sample kit suitable for Oil analysis, including additional Acid Number and Base Number tests.
How do I take a good sample?
Copper, Iron, Chromium, Lead, Aluminium, Silicon, Tin, Nickel, Sodium, Potassium, Molybdenum, Calcium, Magnesium, Phosphorus, Zinc, Titanium, Antimony, Vanadium, Boron, Sulfur, Silver, Manganese, Cadmium, Barium, Lithium.
@40 Degrees Celcius, @100 Degrees Celcius.
% Fuel in oil via Gas Chromatograph.
Water, Visual Deposits.
Soot, Oxidation, Nitration, Sulphation, Water.
PQ Index.
ISO Cleanliness via ISO 4406.2, >4, >6, >10, >14, >18, >21, >38 and >50 Micron channel counts.
TAN and TBN readings (reported in mg KOH/g).
* Included analytes aligned to compartment types.
In addition to what is contained in your Sample Kit, You will need one of the following items in order to take your sample. If your machine is fitted with a live sampling point, you will need to use the live sampling probe. Otherwise, if you wish to take the sample through the dipstick tube, you should use the vacuum pump that is suitable for your working environment.