SOS13 - Oil Sample Kit With Additional RULER Analysis

Sample kit suitable for Oil analysis, including additional RULER (Remaining Useful Life) test.

Order Online

How do I take a good sample?

This kit contains the following items

Analysis included

Elemental Analysis

Copper, Iron, Chromium, Lead, Aluminium, Silicon, Tin, Nickel, Sodium, Potassium, Molybdenum, Calcium, Magnesium, Phosphorus, Zinc, Titanium, Antimony, Vanadium, Boron, Sulfur, Silver, Manganese, Cadmium, Barium, Lithium.

Viscosity

@40 Degrees Celcius.

Karl Fischer Analysis

Water (ppm).

FTIR

Oxidation, Nitration.

Ferrous Content

PQ Index.

Physical Testing

Colour (ASTM D1500), Visual Deposits.

Particle Count

ISO Cleanliness via ISO 4406.2, >4, >6, >10, >14, >18, >21, >38 and >50 Micron channel counts.

Acid Number

TAN reading (reported in mg KOH/g).

Oil Condition Analysis

Remaining Useful Life Evaluation Analysis Routine (RULER), Varnish Potential Test (MPC).

Before taking a sample

In addition to what is contained in your Sample Kit, You will need one of the following items in order to take your sample. If your machine is fitted with a live sampling point, you will need to use the live sampling probe. Otherwise, if you wish to take the sample through the dipstick tube, you should use the vacuum pump that is suitable for your working environment.