Sample kit suitable for standard Oil or Coolant analysis, including a disposable (single use) vacuum pump.
How do I take a good sample?
Copper, Iron, Chromium, Lead, Aluminium, Silicon, Tin, Nickel, Sodium, Potassium, Molybdenum, Calcium, Magnesium, Phosphorus, Zinc, Titanium, Antimony, Vanadium, Boron, Sulphur, Silver, Manganese, Cadmium, Barium.
@ 40 Degress Celcius, @ 100 Degrees Celcius.
% Fuel in oil via Gas Chromatograph.
Water, Visual Deposits.
Soot, Oxidation, Nitration, Sulphation.
Ferrous content.
ISO Cleanliness via ISO 4406.2, >4, >6, >10, >14, >18, >21, >38 and >50 Micron readings.
* Included analytes aligned to compartment types.
Copper, Iron, Lead, Aluminium, Silicon, Tin, Sodium, Potassium, Molybdenum, Calcium, Magnesium, Phosphorus, Zinc, Boron, Sulfur.
pH (Hydrogen Ion Concentration), EC (Electrical Conductivity), % Glycol, Total Hardness (Calcium Carbonate - CaCO3).
Precipitate, Solution, Appearance, Coolant Colour, Olfactory, Foaming, Contaminants.
Nitrite, Nitrate, Glycolate, Chloride, Sulphate.