Sample kit is suitable for wear debris analysis for filter mediums. For wear debris analysis on oil samples or manual particle counting, you must include an additional standard SOS3 sample bottle (from an SOS3 kit) in the SOS4 box and clearly indicate the preferred analysis.
Copper, Iron, Chromium, Lead, Aluminium, Silicon, Tin, Nickel, Sodium, Potassium, Molybdenum, Calcium, Magnesium, Phosphorus, Zinc, Titanium, Antimony, Vanadium, Boron, Sulfur, Silver, Manganese, Cadmium, Barium, Lithium.
@40 Degrees Celcius, @100 Degrees Celcius.
% Fuel in oil via Gas Chromatograph.
Water, Visual Deposits.
Soot, Oxidation, Nitration, Sulphation, Water.
PQ Index.
ISO Cleanliness via ISO 4406.2, >4, >6, >10, >14, >18, >21, >38 and >50 Micron channel counts.
Scaled Primary Photograph.
Scaled Secondary Photograph.
Particle Size Distribution %.
Particle Wear Mechanism %.
Particle Identification %.
- Or -
Optical Microscope Particle Count via ISO 4407 **.
* Included analytes aligned to compartment types.
** Available upon special request.
PQ Index.
Scaled Primary Photograph.
Scaled Secondary Photograph.
Particle Size Distribution %.
Particle Wear Mechanism %.
Particle Identification %.
Please read these instructions before taking a filtergram sample.